1.
Chinese Journal of Radiological Medicine and Protection ; (12): 225-227, 2014.
Article in Chinese | WPRIM | ID: wpr-443833

ABSTRACT

Objective To investigate optimal radiation dose for digital radiography by researching the correlation between radiation dose and image quality of high kV chest radiography.Methods The kV of chest radiography was setted on 120 kV while mAs was changed.The chest radiography phantom and the contrast detail phantom CDRAD2.0 were exposed by DR with different mAs from 1 to 25 mAs.The entrance doses were measured for all exposures and the images were read independently by 5 observers on a higher resolution monitor of diagnosis work station.The image quality figure (IQF) was measured for each image.Comparison of the mean IQFs with different exposure doses were conducted in order to determined which was the optimal exposure condition for high kV radiography.The image quality of normal adult using different mAs,4 and 10 mAs for high KV chest radiography was compared.Results When the mAs was increased from 1 to 25 mAs,the entrance doses varied from 0.067 to 1.468 mGy.With the entrance doses increasing,the value of IQF was decreased (F =31.00,P < 0.05).The values of IQF were statistically different between 1 and 4 mAs(F =15.3,P <0.05),and between 10 and 25 mAs(F =9.74,P <0.05).At 4 and 10 mAs with the entrance dose 0.250 and 0.606 mGy,the synthesis score of chest high kV radiography from two kinds of exposure dose was (24.8 ± 1.64),(25.8 ± 2.05),with no statistically significant difference.Conclusions For digital radiography,increasing radiation dose can improve image information.The optimal entrance dose of high kV chest radiography for standard body was about 0.250 mGy.

2.
Chinese Journal of Radiology ; (12): 632-636, 2011.
Article in Chinese | WPRIM | ID: wpr-416558

ABSTRACT

Objective To study the diagnostic value of susceptibility weighted imaging (SWI) in diffuse axonal injury (DAI) and investigate the relationship between SWI and clinical prognosis. MethodsTwenty patients (15 males and 5 females) with DAI were included in this study. Routine sequences (T1WI, T2WI and FLAIR) and SWI were performed on a 3.0 T MRI scanner. There were 8 cases whose Glasgow score scale (GCS) ranged from 3.0 to 5.0, 4 cases from 6.0 to 8.0 and 8 from 9.0 to 12.0. The interval time between injury and examination were from 3 hours to 20 days. The number and volume of lesions observed on SWI and routine sequence were compared using Mann-Whitney U-test and paired t-test. Pearson correlation was used to analyze the relationship between the number and volume of all lesions and GCS. Results The lesions showed punctate, beaded, patchy and cord-like hypointense signal with various size on SWI (lesion diameter <2.0 cm). Distribution of lesions was multifocal with clear boundary. Routine MRI scan found a total of 78 lesions, while SWI sequence detected 424 lesions. The number of the lesions found on SWI was more than that on conventional MRI (U=-15.447,P<0.01). The total volume of the lesions measured on routine MRI and SWI were 19 340 mm3 and 38 042 mm3, respectively. The total volume measured on SWI was more than that on routine MR (t=5.870,P<0.01). The number and volume of all lesions were negatively correlated with GCS (r=-0.802, -0.767, P<0.01). Conclusion SWI sequence could find more bleeding lesions than the routine MRI sequences. The number and the volume of the lesions were closely related to GCS. SWI showed high value in the diagnosis and prediction of the prognosis of DAI.

3.
Chinese Journal of Radiology ; (12): 697-699, 2009.
Article in Chinese | WPRIM | ID: wpr-394078

ABSTRACT

Objective To study the relationship between the selection of tube tension in digitalchest radiograph and image quality.Methods When tube current was fixed at 4 mAs, the choice of X-ray tube voltage changed from 60 to 120 kV.CDRAD2.0 contrast details phantom and normal human chest were exposed by X-ray system with 7 kinds of tube voltage (the difference between tube voltage was 10 kV) ,and the X-ray incidental dose of phantom surface was measured.Five radiologists with 3 years working experience evaluated the image quality on monitor and calculated the image quality factor (IQF) and image reading score.Statistics analysis was then performed by using ANOVA test and t test.According to the results, the optimum tube voltage range was determined.Results (1) The incidental dose of phantom surface increased with the higher tube voltage.(2)When the tube voltage was changed from 60 kV to 120 kV, the IQF value observed in CDRAD2.0 phantom image on monitor was 75.0±10.4,57.1±6.4,52.7±2.5,47.9±4.5, 46.0±3.8,46.0±2.8,45.2±3.5 ,there was significant statistical differences between groups(F=19.10, P<0.01).(3)The integrated score of the chest image quality in the tube voltage 90 kV and 120 kV were 12.4±0.9 and 13.0±0.7, respectively, and there was no statistical difference between two groups(t= 1.500,P>0.05).Conclusions (1)With the increase of tube tension,the display capacity of display device gradually strengthened.When the tube tension exceeded 90 kV, the increase of image quality on monitor was not evident.(2) With proper radiation dose, the value of tube tension in digital X-ray chest photograph was about 90 kV.